English – Global / English
English – Global / English
Europe
  • Poland – Polski Poland – Polski
  • Lithuania – Lithuanian Lithuania – Lithuanian
  • Netherlands – Dutch Netherlands – Dutch
  • Denmark – Danish Denmark – Danish
  • Estonia – Estonian Estonia – Estonian
  • Finland – Finnish Finland – Finnish
  • France – French France – French
  • Greece – Greek Greece – Greek
  • Italy – Italian Italy – Italian
  • Latvia – Latvian Latvia – Latvian
  • Portugal – Portuguese Portugal – Portuguese
  • Romania – Romanian Romania – Romanian
  • Slovenia – Slovenian Slovenia – Slovenian
  • Spain – Spanish Spain – Spanish
  • Austria – German Austria – German
  • Germany – German Germany – German
  • Switzerland – German Switzerland – German
  • Czech Republic– Czech Czech Republic– Czech
  • Sweden – Swedish Sweden – Swedish
  • Liechtenstein – German Liechtenstein – German
  • Slovakia – Slovak Slovakia – Slovak
  • Ukraine – Ukrainian Ukraine – Ukrainian
  • Moldova – Romanian Moldova – Romanian
  • Cyprus – Greek Cyprus – Greek
  • Ukraine – Russian Ukraine – Russian
  • Croatia – Croatian Croatia – Croatian
  • Bulgaria – Bulgarian Bulgaria – Bulgarian
  • Malta – English Malta – English
Asia & Central Asia
  • China – Chinese China – Chinese
  • Japan – Japanese Japan – Japanese
  • Tajikistan – Russian Tajikistan – Russian
  • Kazakhstan – Russian Kazakhstan – Russian
  • Uzbekistan – Russian Uzbekistan – Russian
  • Kyrgyzstan – Russian Kyrgyzstan – Russian
  • United Arab Emirates – English United Arab Emirates – English
  • Qatar – English Qatar – English
Other Regions
  • New Zealand – English New Zealand – English
  • Singapore – English Singapore – English
  • England – English England – English
  • Seychelles – English Seychelles – English
English – Global / English
English – Global / English
Europe
  • Poland – Polski Poland – Polski
  • Lithuania – Lithuanian Lithuania – Lithuanian
  • Netherlands – Dutch Netherlands – Dutch
  • Denmark – Danish Denmark – Danish
  • Estonia – Estonian Estonia – Estonian
  • Finland – Finnish Finland – Finnish
  • France – French France – French
  • Greece – Greek Greece – Greek
  • Italy – Italian Italy – Italian
  • Latvia – Latvian Latvia – Latvian
  • Portugal – Portuguese Portugal – Portuguese
  • Romania – Romanian Romania – Romanian
  • Slovenia – Slovenian Slovenia – Slovenian
  • Spain – Spanish Spain – Spanish
  • Austria – German Austria – German
  • Germany – German Germany – German
  • Switzerland – German Switzerland – German
  • Czech Republic– Czech Czech Republic– Czech
  • Sweden – Swedish Sweden – Swedish
  • Liechtenstein – German Liechtenstein – German
  • Slovakia – Slovak Slovakia – Slovak
  • Ukraine – Ukrainian Ukraine – Ukrainian
  • Moldova – Romanian Moldova – Romanian
  • Cyprus – Greek Cyprus – Greek
  • Ukraine – Russian Ukraine – Russian
  • Croatia – Croatian Croatia – Croatian
  • Bulgaria – Bulgarian Bulgaria – Bulgarian
  • Malta – English Malta – English
Asia & Central Asia
  • China – Chinese China – Chinese
  • Japan – Japanese Japan – Japanese
  • Tajikistan – Russian Tajikistan – Russian
  • Kazakhstan – Russian Kazakhstan – Russian
  • Uzbekistan – Russian Uzbekistan – Russian
  • Kyrgyzstan – Russian Kyrgyzstan – Russian
  • United Arab Emirates – English United Arab Emirates – English
  • Qatar – English Qatar – English
Other Regions
  • New Zealand – English New Zealand – English
  • Singapore – English Singapore – English
  • England – English England – English
  • Seychelles – English Seychelles – English

Heat recovery dehumidifier with inverter compressor MSHA(C)-***IX series

The MSHA(C) series dehumidifiers combine the functions of dehumidification and fresh air supply, have three-stage filtration (including HEPA and UV disinfection) and provide clean, fresh air. Thanks to energy-saving modes, automation and an intelligent touch controller, these units are characterized by ease of operation, low maintenance costs and high indoor comfort.
Air flow rate: 6800 м³/h
Dehumidification capacity: 28 ... 500 l/24h

Want to buy or have questions?
Heat recovery dehumidifier with inverter compressor MSHA(C)-***IX series

The dehumidifiers of MSHA(C) series are equipped with three* air filtering stages. They are notable for their low maintenance cost and power saving capabilities. These dehumidifiers are fully automated and convenient to operate. Ducted design of this dehumidifiers allows concealed installation.

KEY ADVANTAGES

  • The electronic expansion valve controls the precise amount of refrigerant flow, 
 optimizing refrigeration cycle efficiency.
  • The product comes circuit board and wired wall controller, the touch screen controller has user friendly interface what simplifies user experience.
  • The product has its own positive pressure drainage function. lt can drain water smoothly without reserving a water trap, greatly reducing the height of the ceiling.
  • The product integrates fresh air and dehumidification into one system with minimal maintenance costs, improved comfort and energy savings.
  • The product has a touch-screen intelligent controller with a memory function for user’s settings in case of black-out or power failure.
  • The product comes with primary, medium and HEPA filter to remove hair, pet fur, dust, smoke particles, fine dust, pollen and PM2.5 particles in the air. It has UV light and negative ion generator to ensure fresh and clean indoor air.*
  • The product is designed through professional calculation and simulation software to ensure that the coils and pipeline match cooling & heating capacity & circulating air volume, optimize the performance while keep the size compact.
  • The heat exchange coil is made of high-efficiency copper tubes with blue hydrophiliccoated aluminum fins. The condensate pan is made of SUS304. Enforced filter replacement function further improves the quality of air purification and the service life of the product.

 

COMPONENTS

 

MyCond MSHA(C)-***IX series electronic expansion valve (EEV)

Electronic Expansion Valve (EEV) is an advanced refrigeration component that precisely controls the flow of refrigerant into an evaporator based on real-time system conditions like temperature and pressure, using an electronic controller and a small motor. It offers superior energy efficiency and performance compared to traditional mechanical valves by adapting to changing loads, making it crucial for modern HVAC systems.


DC inverter compressor

MyCond MSHA(C)-***IX series compressor with inverter motor


EC inverter fan motor

MyCond MSHA(C)-***IX series inverter fan motor


Intelligent control

MyCond MSHA(C)-***IX series intelligent control screen

 

Fresh air dehumidification (external circulation)

Mix the fresh air and return air and process the mixed air to keep the indoor air fresh and dry.

Fresh air introduction

Intelligent introduction of outdoor air to keep the indoor air fresh.lt is suitable for indoor humidity < 60%RH.

Return air dehumidification (internal circulation)

Energy-saving dehumidification mode, lower energy consumption for continuous operation. Suitable for indoor humidity <75%RH.

 

STANDART

Specifications Units MSHA(C)-60IX MSHA(C)-100IX MSHA(C)-140IX MSHA(C)-180IX
Test condition 30°C, 80%
Dehumidification l/day 60 100 140 180
Fan type  Stepless speed control (0-10V)
Total air supply volume m³/h 650-780 1000-1200 1200-1350 1700-2200
Supply air residual pressure Pa 100 100 100 200
Return air volume m³/h 780-550 680-800 750-850 1600-2200
Fresh air volume m³/h 0-230 0-400 0-500 0-600
Power/Current W/A 950/4.3 1450/6.5 1680/7.6 1830/3.8
Voltage/Frequency V/Hz 220/50 220/50 220/50 380/50
Control method Full touch LCD
Electricity/Ingress protection (IP) Class I/IPX3
Noise dB(A) <45 <48
Compressor Panasonic/Embraco, інвертор, R32
Gas charge g 600 700 750 1600
Return air sensor 5-in-1 multifunction
New air valve Built-in
Heat exchanger Hydrophilic aluminum foil purple copper tube
Drain pan pipe diameter Ø20 Ø32
Filtration (standard) Primary/Intermediate/High Efficiency Primary/Intermediate
Purification (standard) Negative ion/UV sterilization
Size mm 1090×689×310 1150×819×600
Net weight kg 70 70 73 110
Fresh air port mm Ø150 269×264
Return air port mm Ø200 300×350
Delivery air port mm Ø200 350×350

 

Specifications Units MSHA(C)-250IX MSHA(C)-380IX MSHA(C)-500IX
Test condition 30°C, 80%
Dehumidification l/day 250 380 500
Fan type  Stepless speed control (0-10V)
Total air supply volume m³/h 1900-2700 3500-3850 4800-5300
Supply air residual pressure m³/h   250 250
Return air volume m³/h 2100-2700 2750-3850 3800-5300
Fresh air volume m³/h 0-800 0-1000 0-1500
Power/Current W/A 4200/6.4 6246/11.6 9224/14
Voltage/Frequency V/Hz 380/50 380/50 380/50
Control method Full touch LCD
Electricity/Ingress protection (IP)   Class I/IPX3 Class I/IPX4
Noise dB(A) <48 <50 <55
Compressor  
Gas charge g 1800 2500 2800
Return air sensor 5-in-1 multifunction
New air valve Built-in
Heat exchanger Hydrophilic aluminum foil purple copper tube
Drain pan pipe diameter Ø32
Filtration (standard) Primary/Intermediate
Purification (standard) Negative ion/UV sterilization
Size mm 1150×819×600 1350×1116×720 1350×1116×720
Net weight kg 121 199 202
Fresh air port mm 269×264 373×228 373×228
Return air port mm 300×350 450×430 450×430
Delivery air port mm 350×350 818×313 818×313

 

MODULAR

Specifications Units MSHA(C)-60IX MSHA(C)-100IX MSHA(C)-140IX
Test condition 30°C, 80%
Dehumidification l/day 60 100 140
Fan type  Stepless speed control (0-10V)
Total air supply volume m³/h 650-780 1000-1200 1200-1350
Supply air residual pressure m³/h 100 100 100
Return air volume m³/h 780-550 680-800 750-850
Fresh air volume m³/h 0-230 0-400 0-500
Power/Current W/A 950/4.3 1450/6.5 1680/7.6
Voltage/Frequency V/Hz 220/50 220/50 220/50
Control method Full touch LCD
Electricity/Ingress protection (IP)   Class I/IPX3
Noise dB(A) <45 <45 <45
Compressor Panasonic/Embraco, Inverter, R32
Gas charge g 600 700 750
Return air sensor 5-in-1 multi-function
New air valve Built-in
Heat exchanger Hydrophilic aluminum foil purple copper tube
Drain pan pipe diameter   Ø20 Ø20 Ø20
Filtration (standard) Primary/Intermediate/High Efficiency
Purification (standard) Negative ion/UV sterilization
Size mm 1160×590×325 1200×640×370
Net weight kg 70 70 73
Fresh air port mm Ø150 Ø150 Ø150
Return air port mm Ø200 Ø200 Ø200
Delivery air port mm Ø200 Ø200 Ø200

* 3 stages of filtration available from 28 to 140 models.